Hitachi NAS Platform
Reduce complexity with our robust, reliable, efficient and high-performance Network Attached Storage technology.
HNAS 5200
HNAS 5300
HNAS 5200
| HNAS 5200 | |
| Protocol Support | NFS, SMB, FTP, iSCSI and HTTPS(S3) to the cloud |
| Virtual Cluster Support | Up to 40 nodes |
| Aggregate Performance (GB/s) | 192 |
| Max. Virtual File System/Namespace Size (w/tiering to Object Store) | Unlimited up to max. files per file system/namespace |
| Max. Files per File System/Namespace | 130/840 Billion |
| Max. Mount Points (Shares and Exports) | 20,000 shares, 10,000 exports. |
| Note: Maximum tested configurations are: a) 10k exports with 10k shares, or b) 5k exports with 20k shares | |
| Max. Connections (NFS/SMB) | 64 |
| Max. Concurrent Open Files per Node: SMB | 1.65 million |
| Max. Nodes per Namespace | Up to 4 |
| Max. File Systems per Namespace | 500 |
| Max. File System Capacity per Namespace | 16PB |
| Max. File System Size | 1PB |
| Max. EVS (Enterprise Virtual Servers) per Namespace | 64 |
| Max. Logical Units (LUNs) | 512 |
| Max. LUN Size | 64TB |
| Max. Concurrent FTP Sessions | 10000 |
| SMB/NFS File Name Length | 255 Characters |
| SMB Path Name Length | 65,535 Characters |
| NFS Path Name Length | 1024 Characters |
| iSCSI Targets per EVS | 32 |
| iSCSI LUNs per Target | 32 |
| iSCSI Sessions per Target | 64 |
| iSCSI LUN Size | 256TB |
| Max. VLANS | 4095 |
| Rack Unit Height | 3U |
| Power Supply | Dual |
| Memory on FPGA Board | 96GB/16GB NVRAM |
| Memory on Motherboard | 64GB |
| Random I/O: per Node | 87500 |
| Throughput: MB/sec (Read) per Node | 3,4 |
| Throughput: MB/sec (Write) per Node | 1,3 |
| Throughput: MB/sec (mixed workloads 70/30 read/write) per Node | 3400 |
| Cooling Fans | 2 – Hot Swap |
| Power Supplies | 2 – Hot Swap |
| 10GbE LAN Ports | 6 |
| FC Storage Ports | 4 |
| Voltage Range (Ave/Max) | 100 VAC – 2.1/2.6A |
| 110 VAC – 1.9/2.4A | |
| 200 VAC – 1.0/1.3A | |
| 208 VAC – 1.0/1.3A | |
| 230 VAC – 0.9/1.2A | |
| Power Supply Rating | 495W |
| Average Thermal (BTU/hour) | 710 |
| Max. Thermal (BTU/hour) | 887 |
| Max. Power Usage | 260W |
| Height/Width/Depth | 3U, 5.2 in. (132mm)/ |
| 17.3 in. (440mm)/28.6 in. (725mm) | |
| Weight | 51 lbs. (23kg) |
| Compliance | RoHS 6 |
| China RoHS Compliant | |
| EU RoHS Compliant | |
| Safety | |
| EU: EN62368-1: 2nd edition | |
| Canada: CAN/CSA-C22.2 No.60950-1-07 2nd edition | |
| US: UL 62368-1 | |
| EMC | |
| EU: EN62368-1: 2nd edition | |
| Canada: CAN/CSA-C22.2 No.60950-1-07 2nd edition | |
| US: UL 62368-1 | |
HNAS 5300
| HNAS 5300 | |
| Protocol Support | NFS, SMB, FTP, iSCSI and HTTPS(S3) to the cloud |
| Virtual Cluster Support | Up to 80 nodes |
| Aggregate Performance (GB/s) | 384 |
| Max. Virtual File System/Namespace Size (w/tiering to Object Store) | Unlimited up to max. files per file system/namespace |
| Max. Files per File System/Namespace | 130/840 Billion |
| Max. Mount Points (Shares and Exports) | 20,000 shares, 10,000 exports. |
| Note: Maximum tested configurations are: a) 10k exports with 10k shares, or b) 5k exports with 20k shares | |
| Max. Connections (NFS/SMB) | 64 |
| Max. Concurrent Open Files per Node: SMB | 2.3 million |
| Max. Nodes per Namespace | Up to 8 |
| Max. File Systems per Namespace | 500 |
| Max. File System Capacity per Namespace | 32PB |
| Max. File System Size | 1PB |
| Max. EVS (Enterprise Virtual Servers) per Namespace | 64 |
| Max. Logical Units (LUNs) | 512 |
| Max. LUN Size | 64TB |
| Max. Concurrent FTP Sessions | 10000 |
| SMB/NFS File Name Length | 255 Characters |
| SMB Path Name Length | 65,535 Characters |
| NFS Path Name Length | 1024 Characters |
| iSCSI Targets per EVS | 32 |
| iSCSI LUNs per Target | 32 |
| iSCSI Sessions per Target | 64 |
| iSCSI LUN Size | 256TB |
| Max. VLANS | 4095 |
| Rack Unit Height | 3U |
| Power Supply | Dual |
| Memory on FPGA Board | 96GB/16GB NVRAM |
| Memory on Motherboard | 64GB |
| Random I/O: per Node | 125 |
| Throughput: MB/sec (Read) per Node | 4,8 |
| Throughput: MB/sec (Write) per Node | 1,8 |
| Throughput: MB/sec (mixed workloads 70/30 read/write) per Node | 3,7 |
| Cooling Fans | 2 – Hot Swap |
| Power Supplies | 2 – Hot Swap |
| 10GbE LAN Ports | 6 |
| FC Storage Ports | 4 |
| Voltage Range (Ave/Max) | 100 VAC – 2.1/2.6A |
| 110 VAC – 1.9/2.4A | |
| 200 VAC – 1.0/1.3A | |
| 208 VAC – 1.0/1.3A | |
| 230 VAC – 0.9/1.2A | |
| Power Supply Rating | 495W |
| Average Thermal (BTU/hour) | 710 |
| Max. Thermal (BTU/hour) | 887 |
| Max. Power Usage | 260W |
| Height/Width/Depth | 3U, 5.2 in. (132mm)/ |
| 17.3 in. (440mm)/28.6 in. (725mm) | |
| Weight | 51 lbs. (23kg) |
| Compliance | RoHS 6 |
| China RoHS Compliant | |
| EU RoHS Compliant | |
| Safety | |
| EU: EN62368-1: 2nd edition | |
| Canada: CAN/CSA-C22.2 No.60950-1-07 2nd edition | |
| US: UL 62368-1 | |
| EMC | |
| EU: EN62368-1: 2nd edition | |
| Canada: CAN/CSA-C22.2 No.60950-1-07 2nd edition | |
| US: UL 62368-1 | |